Full DC Inverter R290 Air Source Monoblock Heat Pump
Designed for high efficiency domestic hot water, heating, and cooling. This new energy solution provides stable performance even in extreme cold climates.
| Model Specifications |
08-Nd2 |
10-Nd2 |
12-Nd2 |
14-Nd2 |
16-Nd2 |
| Heating (AT7/6, WT30/35) |
Capacity |
kW |
8 |
10 |
12 |
14 |
16 |
| Input |
kW |
1.62 |
2.08 |
2.45 |
2.74 |
3.25 |
| COP |
W/W |
4.95 |
4.8 |
4.9 |
5.11 |
4.92 |
| SCOP |
35°C |
- |
4.9 |
4.9 |
4.9 |
5.2 |
4.9 |
| 55°C |
- |
3.85 |
3.85 |
3.85 |
3.9 |
3.9 |
| Energy Class (Average Climate) |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
| Refrigerant Type |
- |
R290 |
| Sound Pressure (1m) |
dB |
45 |
49 |
51 |
51 |
51 |
HEATING, COOLING AND DOMESTIC HOT WATER IN ONE SYSTEM
This integrated system provides everything a home needs: heating, cooling, and domestic hot water. It is the ideal alternative for traditional gas or fuel oil heating, allowing for delightful warmth throughout the year.
FOUR TECHNOLOGIES FOR ENERGY-SAVING PERFORMANCE
Technologically advanced components ensure a step ahead in efficiency and sustainability, providing high COP even in low ambient temperatures.
?
Frequently Asked Questions
What is the advantage of using R290 refrigerant?
R290 is a natural refrigerant with a very low Global Warming Potential (GWP). It allows the heat pump to achieve higher water temperatures (up to 75°C) more efficiently than traditional refrigerants.
Can this unit operate in extremely cold weather?
Yes, the EVI DC Inverter technology allows the system to operate reliably in ambient temperatures as low as -30°C, making it suitable for cold climate regions.
Does this system provide both heating and cooling?
Absolutely. It is a 3-in-1 integrated system that provides space heating during winter, space cooling during summer, and domestic hot water all year round.
What is the energy efficiency rating of this heat pump?
This series is rated A+++ for energy efficiency in both 35°C and 55°C water temperature applications, ensuring significant energy savings for homeowners.
How noisy is the outdoor unit during operation?
The unit is designed for quiet operation, with sound pressure levels as low as 45dB to 51dB(a) at a 1-meter distance, depending on the specific model.
Is the installation process complex?
The monoblock design means most components are contained within a single outdoor unit. This "freestanding" installation style simplifies the setup process compared to split systems.